TPress
Manz, Sabina; Seifert, Dirk; Altenburg, Bjoern; Schmalz, Thomas; Dosen, Strahinja; Gonzalez-Vargas, Jose
In: Clinical Biomechanics, Bd. 106, S. 105988, 2023, ISSN: 0268-0033.
Abstract | Links | Schlagwörter: above knee prosthesis, adult, article, C-leg, Challenger, clinical article, controlled study, data analysis software, degree of freedom, endoprosthesis, feasibility study, foot prosthesis, gait, gait analysis system, gait deviation index, Genium X3, Germany, gold standard, human, kinematics, kinetics, knee angle, knee function, knee prosthesis, leg amputation, male, microprocessor, middle aged, motion analysis system, motion sensor, SPSS, strain gauge transducer, Taleo, thigh, Triton, tyloxapol, walk test, walking speed
@article{Manz2023,
title = {Using embedded prosthesis sensors for clinical gait analyses in people with lower limb amputation: A feasibility study},
author = {Sabina Manz and Dirk Seifert and Bjoern Altenburg and Thomas Schmalz and Strahinja Dosen and Jose Gonzalez-Vargas},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2024655048&from=export},
doi = {10.1016/j.clinbiomech.2023.105988},
issn = {0268-0033},
year = {2023},
date = {2023-06-01},
journal = {Clinical Biomechanics},
volume = {106},
pages = {105988},
publisher = {Elsevier BV},
address = {J. Gonzalez-Vargas, Ottobock SE & Co. KGaA, Duderstadt, Germany},
abstract = {Background: Biomechanical gait analyses are typically performed in laboratory settings, and are associated with limitations due to space, marker placement, and tasks that are not representative of the real-world usage of lower limb prostheses. Therefore, the purpose of this study was to investigate the possibility of accurately measuring gait parameters using embedded sensors in a microprocessor-controlled knee joint. Methods: Ten participants were recruited for this study and equipped with a Genium X3 prosthetic knee joint. They performed level walking, stair/ramp descent, and ascent. During these tasks, kinematics and kinetics (sagittal knee and thigh segment angle, and knee moment) were recorded using an optical motion capture system and force plates (gold standard), as well as the prosthesis-embedded sensors. Root mean square errors, relative errors, correlation coefficients, and discrete outcome variables of clinical relevance were calculated and compared between the gold standard and the embedded sensors. Findings: The average root mean square errors were found to be 0.6°, 5.3°, and 0.08 Nm/kg, for the knee angle, thigh angle, and knee moment, respectively. The average relative errors were 0.75% for the knee angle, 11.67% for the thigh angle, and 9.66%, for the knee moment. The discrete outcome variables showed small but significant differences between the two measurement systems for a number of tasks (higher differences only at the thigh). Interpretation: The findings highlight the potential of prosthesis-embedded sensors to accurately measure gait parameters across a wide range of tasks. This paves the way for assessing prosthesis performance in realistic environments outside the lab.},
keywords = {above knee prosthesis, adult, article, C-leg, Challenger, clinical article, controlled study, data analysis software, degree of freedom, endoprosthesis, feasibility study, foot prosthesis, gait, gait analysis system, gait deviation index, Genium X3, Germany, gold standard, human, kinematics, kinetics, knee angle, knee function, knee prosthesis, leg amputation, male, microprocessor, middle aged, motion analysis system, motion sensor, SPSS, strain gauge transducer, Taleo, thigh, Triton, tyloxapol, walk test, walking speed},
pubstate = {published},
tppubtype = {article}
}
Williams, M. R.; D'Andrea, S.; Herr, H. M.
Impact on gait biomechanics of using an active variable impedance prosthetic knee Artikel
In: J. NeuroEng. Rehabil., Bd. 13, Nr. 1, 2016, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: above knee amputation, adult, aged, article, biomechanics, body position, C-leg, clinical article, College Park Trustep, controlled study, female, foot prosthesis, gait, gait biomechanics, hip, hip extension moment, human, knee power, knee prosthesis, Low Profile Vari-Flex, male, musculoskeletal system parameters, priority journal, range of motion, robotic variable impedance prosthetic knee, step length symmetry, torso lean angle, Triton, VI Knee, walking speed
@article{Williams2016,
title = {Impact on gait biomechanics of using an active variable impedance prosthetic knee},
author = {M. R. Williams and S. D'Andrea and H. M. Herr},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L610660431&from=export},
doi = {10.1186/s12984-016-0159-0},
issn = {1743-0003},
year = {2016},
date = {2016-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {13},
number = {1},
address = {M.R. Williams, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States},
abstract = {Background: An above knee amputation can have a significant impact on gait, with substantial deviations in inter-leg symmetry, step length, hip exertion and upper body involvement even when using a current clinical standard of care prosthesis. These differences can produce gait that is less efficient and less comfortable, resulting in slower and shorter distance walking, particularly with long term use. Methods: A robotic variable impedance prosthetic knee (VI Knee) was tested with five individuals (N = 5) with unilateral amputation above the knee at fixed speeds both above and below their normal walking speed. Subject gait was measured as they walked along an instrumented walkway via optical motion capture and force plates in the floor. Each subject's gait while using the VI Knee was compared to that while using their standard of care knee (OttoBock C-Leg). Results: Significant differences (p < 0.05) in walking between the standard of care and variable impedance devices were seen in step length and hip range of motion symmetries, hip extension moment, knee power and torso lean angle. While using the VI Knee, several subjects demonstrated statistically significant improvements in gait, particularly in increased hip range of motion symmetry between affected and intact sides, greater prosthesis knee power and in reducing upper body involvement in the walking task by decreasing forward and affected side lean and reducing the pelvis-torso twist coupling. These changes to torso posture during gait also resulted in increased terminal stance hip flexion moment across subjects. Detriments to gait were also observed in that some subjects exhibited decreased step length symmetry while using the VI Knee compared to the C-Leg. Conclusions: The knee tested represents the potential to improve gait biomechanics and reduce upper body involvement in persons with above knee amputation compared to current standard of care devices. While using the VI Knee, subjects demonstrated statistically significant improvements in several aspects of gait though some were worsened while using the device. It is possible that these negative effects may be mitigated through longer term training and experience with the VI Knee. Given the demonstrated benefits and the potential to reduce or eliminate detriments through training, using a powered device like the VI Knee, particularly over an extended period of time, may help to improve walking performance and comfort.},
keywords = {above knee amputation, adult, aged, article, biomechanics, body position, C-leg, clinical article, College Park Trustep, controlled study, female, foot prosthesis, gait, gait biomechanics, hip, hip extension moment, human, knee power, knee prosthesis, Low Profile Vari-Flex, male, musculoskeletal system parameters, priority journal, range of motion, robotic variable impedance prosthetic knee, step length symmetry, torso lean angle, Triton, VI Knee, walking speed},
pubstate = {published},
tppubtype = {article}
}
Hahn, A.; Lang, M.; Stuckart, C.
In: Medicine, Bd. 95, Nr. 45, 2016, ISSN: 0025-7974.
Abstract | Links | Schlagwörter: above knee prosthesis, adult, amputee, article, C-leg, climbing, cohort analysis, female, gait, Genium, human, major clinical study, male, mobilization, patient attitude, priority journal, retrospective study, toileting, walking
@article{Hahn2016,
title = {Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings},
author = {A. Hahn and M. Lang and C. Stuckart},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L613375887&from=export},
doi = {10.1097/md.0000000000005386},
issn = {0025-7974},
year = {2016},
date = {2016-01-01},
journal = {Medicine},
volume = {95},
number = {45},
address = {A. Hahn, Otto Bock Healthcare Products GmbH, Brehmstrasse 16, Vienna, Austria},
abstract = {The objective of this work is to evaluate whether clinically important factors may predict an individual's capability to utilize the functional benefits provided by an advanced hydraulic, microprocessor-controlled exo-prosthetic knee component. This retrospective cross-sectional cohort analysis investigated the data of above knee amputees captured during routine trial fittings. Prosthetists rated the performance indicators showing the functional benefits of the advanced maneuvering capabilities of the device. Subjects were asked to rate their perception. Simple and multiple linear and logistic regression was applied. Data from 899 subjects with demographics typical for the population were evaluated. Ability to vary gait speed, perform toileting, and ascend stairs were identified as the most sensitive performance predictors. Prior C-Leg users showed benefits during advanced maneuvering. Variables showed plausible and meaningful effects, however, could not claim predictive power. Mobility grade showed the largest effect but also failed to be predictive. Clinical parameters such as etiology, age, mobility grade, and others analyzed here do not suffice to predict individual potential. Daily walking distance may pose a threshold value and be part of a predictive instrument. Decisions based solely on single parameters such as mobility grade rating or walking distance seem to be questionable.},
keywords = {above knee prosthesis, adult, amputee, article, C-leg, climbing, cohort analysis, female, gait, Genium, human, major clinical study, male, mobilization, patient attitude, priority journal, retrospective study, toileting, walking},
pubstate = {published},
tppubtype = {article}
}
Kistenberg, R. S.
Prosthetic choices for people with leg and arm amputations Artikel
In: Phys. Med. Rehabil. Clin. North Am., Bd. 25, Nr. 1, S. 93–115, 2014, ISSN: 1558-1381.
Abstract | Links | Schlagwörter: anatomy, ankle prosthesis, arm amputation, arm movement, arm prosthesis, biomechanics, bone regeneration, C-leg, Delrin, elbow prosthesis, equipment design, finger amputation, functional status, Genium, hand amputation, health care access, Helix3D, hemipelvectomy, hip prosthesis, human, iLIMB Hand, Kevlar, kinematics, knee prosthesis, leg amputation, leg movement, leg prosthesis, microprocessor, motor control, orthopedic shoe, patient preference, physical activity, Power Knee, priority journal, prosthesis complication, public health service, quality of life, rehabilitation care, review, shoulder prosthesis, surgical technique, surgical technology, suspension, thumb amputation
@article{Kistenberg2014,
title = {Prosthetic choices for people with leg and arm amputations},
author = {R. S. Kistenberg},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343297&from=export},
doi = {10.1016/j.pmr.2013.10.001},
issn = {1558-1381},
year = {2014},
date = {2014-01-01},
journal = {Phys. Med. Rehabil. Clin. North Am.},
volume = {25},
number = {1},
pages = {93–115},
address = {R.S. Kistenberg, Georgia Institute of Technology, School of Applied Physiology, 555 14th Street, Atlanta, GA 30318, United States},
abstract = {New technology and materials have advanced prosthetic designs to enable people who rely on artificial limbs to achieve feats never dreamed before. However, the latest and the greatest technology is not appropriate for everyone. The aim of this article is to present contemporary options that are available for people who rely on artificial limbs to enhance their quality of life for mobility and independence. © 2014 Elsevier Inc.},
keywords = {anatomy, ankle prosthesis, arm amputation, arm movement, arm prosthesis, biomechanics, bone regeneration, C-leg, Delrin, elbow prosthesis, equipment design, finger amputation, functional status, Genium, hand amputation, health care access, Helix3D, hemipelvectomy, hip prosthesis, human, iLIMB Hand, Kevlar, kinematics, knee prosthesis, leg amputation, leg movement, leg prosthesis, microprocessor, motor control, orthopedic shoe, patient preference, physical activity, Power Knee, priority journal, prosthesis complication, public health service, quality of life, rehabilitation care, review, shoulder prosthesis, surgical technique, surgical technology, suspension, thumb amputation},
pubstate = {published},
tppubtype = {article}
}
Chitragari, G.; Mahler, D. B.; Sumpio, B. J.; Blume, P. A.; Sumpio, B. E.
Prosthetic options available for the diabetic lower limb amputee Artikel
In: Clin. Podiatr. Med. Surg., Bd. 31, Nr. 1, S. 174–185, 2014, ISSN: 1558-2302.
Abstract | Links | Schlagwörter: ankle prosthesis, below knee prosthesis, C-leg, dermatitis, diabetes mellitus, diabetic patient, fluid control knee, gait, human, Hydraulic knee, iWALK, joint stability, knee function, leg amputation, leg prosthesis, Manual locking Knee, microprocessor knee, mobilization, partial foot amputation, patellar tendon bearing socket, peripheral neuropathy, Polycentric knee, Power Knee, priority journal, Proprio foot, review, Rheo leg, sensory feedback, Single-axis knee, skin abrasion, synovial bursa, total surface bearing socket, treatment indication
@article{Chitragari2014,
title = {Prosthetic options available for the diabetic lower limb amputee},
author = {G. Chitragari and D. B. Mahler and B. J. Sumpio and P. A. Blume and B. E. Sumpio},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343216&from=export},
doi = {10.1016/j.cpm.2013.09.008},
issn = {1558-2302},
year = {2014},
date = {2014-01-01},
journal = {Clin. Podiatr. Med. Surg.},
volume = {31},
number = {1},
pages = {174–185},
address = {B.E. Sumpio, Yale University School of Medicine, 333 Cedar Street, BB 204, New Haven, CT 06520-8062, United States},
abstract = {Although the rate of lower limb amputation in patients with diabetes is decreasing, amputation still remains a major complication of diabetes. Prosthetics have been long used to help amputees ambulate. The last decade has seen many advances in prostheses with the enhanced understanding of the mechanics of ambulation and improved use of technology. This review describes the different types of prosthetic options available for below knee, ankle, and foot amputees, emphasizing the latest advances in prosthetic design. © 2014 Elsevier Inc.},
keywords = {ankle prosthesis, below knee prosthesis, C-leg, dermatitis, diabetes mellitus, diabetic patient, fluid control knee, gait, human, Hydraulic knee, iWALK, joint stability, knee function, leg amputation, leg prosthesis, Manual locking Knee, microprocessor knee, mobilization, partial foot amputation, patellar tendon bearing socket, peripheral neuropathy, Polycentric knee, Power Knee, priority journal, Proprio foot, review, Rheo leg, sensory feedback, Single-axis knee, skin abrasion, synovial bursa, total surface bearing socket, treatment indication},
pubstate = {published},
tppubtype = {article}
}
2023
Manz, Sabina; Seifert, Dirk; Altenburg, Bjoern; Schmalz, Thomas; Dosen, Strahinja; Gonzalez-Vargas, Jose
In: Clinical Biomechanics, Bd. 106, S. 105988, 2023, ISSN: 0268-0033.
Abstract | Links | Schlagwörter: above knee prosthesis, adult, article, C-leg, Challenger, clinical article, controlled study, data analysis software, degree of freedom, endoprosthesis, feasibility study, foot prosthesis, gait, gait analysis system, gait deviation index, Genium X3, Germany, gold standard, human, kinematics, kinetics, knee angle, knee function, knee prosthesis, leg amputation, male, microprocessor, middle aged, motion analysis system, motion sensor, SPSS, strain gauge transducer, Taleo, thigh, Triton, tyloxapol, walk test, walking speed
@article{Manz2023,
title = {Using embedded prosthesis sensors for clinical gait analyses in people with lower limb amputation: A feasibility study},
author = {Sabina Manz and Dirk Seifert and Bjoern Altenburg and Thomas Schmalz and Strahinja Dosen and Jose Gonzalez-Vargas},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2024655048&from=export},
doi = {10.1016/j.clinbiomech.2023.105988},
issn = {0268-0033},
year = {2023},
date = {2023-06-01},
journal = {Clinical Biomechanics},
volume = {106},
pages = {105988},
publisher = {Elsevier BV},
address = {J. Gonzalez-Vargas, Ottobock SE & Co. KGaA, Duderstadt, Germany},
abstract = {Background: Biomechanical gait analyses are typically performed in laboratory settings, and are associated with limitations due to space, marker placement, and tasks that are not representative of the real-world usage of lower limb prostheses. Therefore, the purpose of this study was to investigate the possibility of accurately measuring gait parameters using embedded sensors in a microprocessor-controlled knee joint. Methods: Ten participants were recruited for this study and equipped with a Genium X3 prosthetic knee joint. They performed level walking, stair/ramp descent, and ascent. During these tasks, kinematics and kinetics (sagittal knee and thigh segment angle, and knee moment) were recorded using an optical motion capture system and force plates (gold standard), as well as the prosthesis-embedded sensors. Root mean square errors, relative errors, correlation coefficients, and discrete outcome variables of clinical relevance were calculated and compared between the gold standard and the embedded sensors. Findings: The average root mean square errors were found to be 0.6°, 5.3°, and 0.08 Nm/kg, for the knee angle, thigh angle, and knee moment, respectively. The average relative errors were 0.75% for the knee angle, 11.67% for the thigh angle, and 9.66%, for the knee moment. The discrete outcome variables showed small but significant differences between the two measurement systems for a number of tasks (higher differences only at the thigh). Interpretation: The findings highlight the potential of prosthesis-embedded sensors to accurately measure gait parameters across a wide range of tasks. This paves the way for assessing prosthesis performance in realistic environments outside the lab.},
keywords = {above knee prosthesis, adult, article, C-leg, Challenger, clinical article, controlled study, data analysis software, degree of freedom, endoprosthesis, feasibility study, foot prosthesis, gait, gait analysis system, gait deviation index, Genium X3, Germany, gold standard, human, kinematics, kinetics, knee angle, knee function, knee prosthesis, leg amputation, male, microprocessor, middle aged, motion analysis system, motion sensor, SPSS, strain gauge transducer, Taleo, thigh, Triton, tyloxapol, walk test, walking speed},
pubstate = {published},
tppubtype = {article}
}
2016
Williams, M. R.; D'Andrea, S.; Herr, H. M.
Impact on gait biomechanics of using an active variable impedance prosthetic knee Artikel
In: J. NeuroEng. Rehabil., Bd. 13, Nr. 1, 2016, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: above knee amputation, adult, aged, article, biomechanics, body position, C-leg, clinical article, College Park Trustep, controlled study, female, foot prosthesis, gait, gait biomechanics, hip, hip extension moment, human, knee power, knee prosthesis, Low Profile Vari-Flex, male, musculoskeletal system parameters, priority journal, range of motion, robotic variable impedance prosthetic knee, step length symmetry, torso lean angle, Triton, VI Knee, walking speed
@article{Williams2016,
title = {Impact on gait biomechanics of using an active variable impedance prosthetic knee},
author = {M. R. Williams and S. D'Andrea and H. M. Herr},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L610660431&from=export},
doi = {10.1186/s12984-016-0159-0},
issn = {1743-0003},
year = {2016},
date = {2016-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {13},
number = {1},
address = {M.R. Williams, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States},
abstract = {Background: An above knee amputation can have a significant impact on gait, with substantial deviations in inter-leg symmetry, step length, hip exertion and upper body involvement even when using a current clinical standard of care prosthesis. These differences can produce gait that is less efficient and less comfortable, resulting in slower and shorter distance walking, particularly with long term use. Methods: A robotic variable impedance prosthetic knee (VI Knee) was tested with five individuals (N = 5) with unilateral amputation above the knee at fixed speeds both above and below their normal walking speed. Subject gait was measured as they walked along an instrumented walkway via optical motion capture and force plates in the floor. Each subject's gait while using the VI Knee was compared to that while using their standard of care knee (OttoBock C-Leg). Results: Significant differences (p < 0.05) in walking between the standard of care and variable impedance devices were seen in step length and hip range of motion symmetries, hip extension moment, knee power and torso lean angle. While using the VI Knee, several subjects demonstrated statistically significant improvements in gait, particularly in increased hip range of motion symmetry between affected and intact sides, greater prosthesis knee power and in reducing upper body involvement in the walking task by decreasing forward and affected side lean and reducing the pelvis-torso twist coupling. These changes to torso posture during gait also resulted in increased terminal stance hip flexion moment across subjects. Detriments to gait were also observed in that some subjects exhibited decreased step length symmetry while using the VI Knee compared to the C-Leg. Conclusions: The knee tested represents the potential to improve gait biomechanics and reduce upper body involvement in persons with above knee amputation compared to current standard of care devices. While using the VI Knee, subjects demonstrated statistically significant improvements in several aspects of gait though some were worsened while using the device. It is possible that these negative effects may be mitigated through longer term training and experience with the VI Knee. Given the demonstrated benefits and the potential to reduce or eliminate detriments through training, using a powered device like the VI Knee, particularly over an extended period of time, may help to improve walking performance and comfort.},
keywords = {above knee amputation, adult, aged, article, biomechanics, body position, C-leg, clinical article, College Park Trustep, controlled study, female, foot prosthesis, gait, gait biomechanics, hip, hip extension moment, human, knee power, knee prosthesis, Low Profile Vari-Flex, male, musculoskeletal system parameters, priority journal, range of motion, robotic variable impedance prosthetic knee, step length symmetry, torso lean angle, Triton, VI Knee, walking speed},
pubstate = {published},
tppubtype = {article}
}
Hahn, A.; Lang, M.; Stuckart, C.
In: Medicine, Bd. 95, Nr. 45, 2016, ISSN: 0025-7974.
Abstract | Links | Schlagwörter: above knee prosthesis, adult, amputee, article, C-leg, climbing, cohort analysis, female, gait, Genium, human, major clinical study, male, mobilization, patient attitude, priority journal, retrospective study, toileting, walking
@article{Hahn2016,
title = {Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings},
author = {A. Hahn and M. Lang and C. Stuckart},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L613375887&from=export},
doi = {10.1097/md.0000000000005386},
issn = {0025-7974},
year = {2016},
date = {2016-01-01},
journal = {Medicine},
volume = {95},
number = {45},
address = {A. Hahn, Otto Bock Healthcare Products GmbH, Brehmstrasse 16, Vienna, Austria},
abstract = {The objective of this work is to evaluate whether clinically important factors may predict an individual's capability to utilize the functional benefits provided by an advanced hydraulic, microprocessor-controlled exo-prosthetic knee component. This retrospective cross-sectional cohort analysis investigated the data of above knee amputees captured during routine trial fittings. Prosthetists rated the performance indicators showing the functional benefits of the advanced maneuvering capabilities of the device. Subjects were asked to rate their perception. Simple and multiple linear and logistic regression was applied. Data from 899 subjects with demographics typical for the population were evaluated. Ability to vary gait speed, perform toileting, and ascend stairs were identified as the most sensitive performance predictors. Prior C-Leg users showed benefits during advanced maneuvering. Variables showed plausible and meaningful effects, however, could not claim predictive power. Mobility grade showed the largest effect but also failed to be predictive. Clinical parameters such as etiology, age, mobility grade, and others analyzed here do not suffice to predict individual potential. Daily walking distance may pose a threshold value and be part of a predictive instrument. Decisions based solely on single parameters such as mobility grade rating or walking distance seem to be questionable.},
keywords = {above knee prosthesis, adult, amputee, article, C-leg, climbing, cohort analysis, female, gait, Genium, human, major clinical study, male, mobilization, patient attitude, priority journal, retrospective study, toileting, walking},
pubstate = {published},
tppubtype = {article}
}
2014
Kistenberg, R. S.
Prosthetic choices for people with leg and arm amputations Artikel
In: Phys. Med. Rehabil. Clin. North Am., Bd. 25, Nr. 1, S. 93–115, 2014, ISSN: 1558-1381.
Abstract | Links | Schlagwörter: anatomy, ankle prosthesis, arm amputation, arm movement, arm prosthesis, biomechanics, bone regeneration, C-leg, Delrin, elbow prosthesis, equipment design, finger amputation, functional status, Genium, hand amputation, health care access, Helix3D, hemipelvectomy, hip prosthesis, human, iLIMB Hand, Kevlar, kinematics, knee prosthesis, leg amputation, leg movement, leg prosthesis, microprocessor, motor control, orthopedic shoe, patient preference, physical activity, Power Knee, priority journal, prosthesis complication, public health service, quality of life, rehabilitation care, review, shoulder prosthesis, surgical technique, surgical technology, suspension, thumb amputation
@article{Kistenberg2014,
title = {Prosthetic choices for people with leg and arm amputations},
author = {R. S. Kistenberg},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343297&from=export},
doi = {10.1016/j.pmr.2013.10.001},
issn = {1558-1381},
year = {2014},
date = {2014-01-01},
journal = {Phys. Med. Rehabil. Clin. North Am.},
volume = {25},
number = {1},
pages = {93–115},
address = {R.S. Kistenberg, Georgia Institute of Technology, School of Applied Physiology, 555 14th Street, Atlanta, GA 30318, United States},
abstract = {New technology and materials have advanced prosthetic designs to enable people who rely on artificial limbs to achieve feats never dreamed before. However, the latest and the greatest technology is not appropriate for everyone. The aim of this article is to present contemporary options that are available for people who rely on artificial limbs to enhance their quality of life for mobility and independence. © 2014 Elsevier Inc.},
keywords = {anatomy, ankle prosthesis, arm amputation, arm movement, arm prosthesis, biomechanics, bone regeneration, C-leg, Delrin, elbow prosthesis, equipment design, finger amputation, functional status, Genium, hand amputation, health care access, Helix3D, hemipelvectomy, hip prosthesis, human, iLIMB Hand, Kevlar, kinematics, knee prosthesis, leg amputation, leg movement, leg prosthesis, microprocessor, motor control, orthopedic shoe, patient preference, physical activity, Power Knee, priority journal, prosthesis complication, public health service, quality of life, rehabilitation care, review, shoulder prosthesis, surgical technique, surgical technology, suspension, thumb amputation},
pubstate = {published},
tppubtype = {article}
}
Chitragari, G.; Mahler, D. B.; Sumpio, B. J.; Blume, P. A.; Sumpio, B. E.
Prosthetic options available for the diabetic lower limb amputee Artikel
In: Clin. Podiatr. Med. Surg., Bd. 31, Nr. 1, S. 174–185, 2014, ISSN: 1558-2302.
Abstract | Links | Schlagwörter: ankle prosthesis, below knee prosthesis, C-leg, dermatitis, diabetes mellitus, diabetic patient, fluid control knee, gait, human, Hydraulic knee, iWALK, joint stability, knee function, leg amputation, leg prosthesis, Manual locking Knee, microprocessor knee, mobilization, partial foot amputation, patellar tendon bearing socket, peripheral neuropathy, Polycentric knee, Power Knee, priority journal, Proprio foot, review, Rheo leg, sensory feedback, Single-axis knee, skin abrasion, synovial bursa, total surface bearing socket, treatment indication
@article{Chitragari2014,
title = {Prosthetic options available for the diabetic lower limb amputee},
author = {G. Chitragari and D. B. Mahler and B. J. Sumpio and P. A. Blume and B. E. Sumpio},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343216&from=export},
doi = {10.1016/j.cpm.2013.09.008},
issn = {1558-2302},
year = {2014},
date = {2014-01-01},
journal = {Clin. Podiatr. Med. Surg.},
volume = {31},
number = {1},
pages = {174–185},
address = {B.E. Sumpio, Yale University School of Medicine, 333 Cedar Street, BB 204, New Haven, CT 06520-8062, United States},
abstract = {Although the rate of lower limb amputation in patients with diabetes is decreasing, amputation still remains a major complication of diabetes. Prosthetics have been long used to help amputees ambulate. The last decade has seen many advances in prostheses with the enhanced understanding of the mechanics of ambulation and improved use of technology. This review describes the different types of prosthetic options available for below knee, ankle, and foot amputees, emphasizing the latest advances in prosthetic design. © 2014 Elsevier Inc.},
keywords = {ankle prosthesis, below knee prosthesis, C-leg, dermatitis, diabetes mellitus, diabetic patient, fluid control knee, gait, human, Hydraulic knee, iWALK, joint stability, knee function, leg amputation, leg prosthesis, Manual locking Knee, microprocessor knee, mobilization, partial foot amputation, patellar tendon bearing socket, peripheral neuropathy, Polycentric knee, Power Knee, priority journal, Proprio foot, review, Rheo leg, sensory feedback, Single-axis knee, skin abrasion, synovial bursa, total surface bearing socket, treatment indication},
pubstate = {published},
tppubtype = {article}
}
2023
Manz, Sabina; Seifert, Dirk; Altenburg, Bjoern; Schmalz, Thomas; Dosen, Strahinja; Gonzalez-Vargas, Jose
In: Clinical Biomechanics, Bd. 106, S. 105988, 2023, ISSN: 0268-0033.
@article{Manz2023,
title = {Using embedded prosthesis sensors for clinical gait analyses in people with lower limb amputation: A feasibility study},
author = {Sabina Manz and Dirk Seifert and Bjoern Altenburg and Thomas Schmalz and Strahinja Dosen and Jose Gonzalez-Vargas},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2024655048&from=export},
doi = {10.1016/j.clinbiomech.2023.105988},
issn = {0268-0033},
year = {2023},
date = {2023-06-01},
journal = {Clinical Biomechanics},
volume = {106},
pages = {105988},
publisher = {Elsevier BV},
address = {J. Gonzalez-Vargas, Ottobock SE & Co. KGaA, Duderstadt, Germany},
abstract = {Background: Biomechanical gait analyses are typically performed in laboratory settings, and are associated with limitations due to space, marker placement, and tasks that are not representative of the real-world usage of lower limb prostheses. Therefore, the purpose of this study was to investigate the possibility of accurately measuring gait parameters using embedded sensors in a microprocessor-controlled knee joint. Methods: Ten participants were recruited for this study and equipped with a Genium X3 prosthetic knee joint. They performed level walking, stair/ramp descent, and ascent. During these tasks, kinematics and kinetics (sagittal knee and thigh segment angle, and knee moment) were recorded using an optical motion capture system and force plates (gold standard), as well as the prosthesis-embedded sensors. Root mean square errors, relative errors, correlation coefficients, and discrete outcome variables of clinical relevance were calculated and compared between the gold standard and the embedded sensors. Findings: The average root mean square errors were found to be 0.6°, 5.3°, and 0.08 Nm/kg, for the knee angle, thigh angle, and knee moment, respectively. The average relative errors were 0.75% for the knee angle, 11.67% for the thigh angle, and 9.66%, for the knee moment. The discrete outcome variables showed small but significant differences between the two measurement systems for a number of tasks (higher differences only at the thigh). Interpretation: The findings highlight the potential of prosthesis-embedded sensors to accurately measure gait parameters across a wide range of tasks. This paves the way for assessing prosthesis performance in realistic environments outside the lab.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
2016
Williams, M. R.; D'Andrea, S.; Herr, H. M.
Impact on gait biomechanics of using an active variable impedance prosthetic knee Artikel
In: J. NeuroEng. Rehabil., Bd. 13, Nr. 1, 2016, ISSN: 1743-0003.
@article{Williams2016,
title = {Impact on gait biomechanics of using an active variable impedance prosthetic knee},
author = {M. R. Williams and S. D'Andrea and H. M. Herr},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L610660431&from=export},
doi = {10.1186/s12984-016-0159-0},
issn = {1743-0003},
year = {2016},
date = {2016-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {13},
number = {1},
address = {M.R. Williams, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, United States},
abstract = {Background: An above knee amputation can have a significant impact on gait, with substantial deviations in inter-leg symmetry, step length, hip exertion and upper body involvement even when using a current clinical standard of care prosthesis. These differences can produce gait that is less efficient and less comfortable, resulting in slower and shorter distance walking, particularly with long term use. Methods: A robotic variable impedance prosthetic knee (VI Knee) was tested with five individuals (N = 5) with unilateral amputation above the knee at fixed speeds both above and below their normal walking speed. Subject gait was measured as they walked along an instrumented walkway via optical motion capture and force plates in the floor. Each subject's gait while using the VI Knee was compared to that while using their standard of care knee (OttoBock C-Leg). Results: Significant differences (p < 0.05) in walking between the standard of care and variable impedance devices were seen in step length and hip range of motion symmetries, hip extension moment, knee power and torso lean angle. While using the VI Knee, several subjects demonstrated statistically significant improvements in gait, particularly in increased hip range of motion symmetry between affected and intact sides, greater prosthesis knee power and in reducing upper body involvement in the walking task by decreasing forward and affected side lean and reducing the pelvis-torso twist coupling. These changes to torso posture during gait also resulted in increased terminal stance hip flexion moment across subjects. Detriments to gait were also observed in that some subjects exhibited decreased step length symmetry while using the VI Knee compared to the C-Leg. Conclusions: The knee tested represents the potential to improve gait biomechanics and reduce upper body involvement in persons with above knee amputation compared to current standard of care devices. While using the VI Knee, subjects demonstrated statistically significant improvements in several aspects of gait though some were worsened while using the device. It is possible that these negative effects may be mitigated through longer term training and experience with the VI Knee. Given the demonstrated benefits and the potential to reduce or eliminate detriments through training, using a powered device like the VI Knee, particularly over an extended period of time, may help to improve walking performance and comfort.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
Hahn, A.; Lang, M.; Stuckart, C.
In: Medicine, Bd. 95, Nr. 45, 2016, ISSN: 0025-7974.
@article{Hahn2016,
title = {Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings},
author = {A. Hahn and M. Lang and C. Stuckart},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L613375887&from=export},
doi = {10.1097/md.0000000000005386},
issn = {0025-7974},
year = {2016},
date = {2016-01-01},
journal = {Medicine},
volume = {95},
number = {45},
address = {A. Hahn, Otto Bock Healthcare Products GmbH, Brehmstrasse 16, Vienna, Austria},
abstract = {The objective of this work is to evaluate whether clinically important factors may predict an individual's capability to utilize the functional benefits provided by an advanced hydraulic, microprocessor-controlled exo-prosthetic knee component. This retrospective cross-sectional cohort analysis investigated the data of above knee amputees captured during routine trial fittings. Prosthetists rated the performance indicators showing the functional benefits of the advanced maneuvering capabilities of the device. Subjects were asked to rate their perception. Simple and multiple linear and logistic regression was applied. Data from 899 subjects with demographics typical for the population were evaluated. Ability to vary gait speed, perform toileting, and ascend stairs were identified as the most sensitive performance predictors. Prior C-Leg users showed benefits during advanced maneuvering. Variables showed plausible and meaningful effects, however, could not claim predictive power. Mobility grade showed the largest effect but also failed to be predictive. Clinical parameters such as etiology, age, mobility grade, and others analyzed here do not suffice to predict individual potential. Daily walking distance may pose a threshold value and be part of a predictive instrument. Decisions based solely on single parameters such as mobility grade rating or walking distance seem to be questionable.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
2014
Kistenberg, R. S.
Prosthetic choices for people with leg and arm amputations Artikel
In: Phys. Med. Rehabil. Clin. North Am., Bd. 25, Nr. 1, S. 93–115, 2014, ISSN: 1558-1381.
@article{Kistenberg2014,
title = {Prosthetic choices for people with leg and arm amputations},
author = {R. S. Kistenberg},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343297&from=export},
doi = {10.1016/j.pmr.2013.10.001},
issn = {1558-1381},
year = {2014},
date = {2014-01-01},
journal = {Phys. Med. Rehabil. Clin. North Am.},
volume = {25},
number = {1},
pages = {93–115},
address = {R.S. Kistenberg, Georgia Institute of Technology, School of Applied Physiology, 555 14th Street, Atlanta, GA 30318, United States},
abstract = {New technology and materials have advanced prosthetic designs to enable people who rely on artificial limbs to achieve feats never dreamed before. However, the latest and the greatest technology is not appropriate for everyone. The aim of this article is to present contemporary options that are available for people who rely on artificial limbs to enhance their quality of life for mobility and independence. © 2014 Elsevier Inc.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
Chitragari, G.; Mahler, D. B.; Sumpio, B. J.; Blume, P. A.; Sumpio, B. E.
Prosthetic options available for the diabetic lower limb amputee Artikel
In: Clin. Podiatr. Med. Surg., Bd. 31, Nr. 1, S. 174–185, 2014, ISSN: 1558-2302.
@article{Chitragari2014,
title = {Prosthetic options available for the diabetic lower limb amputee},
author = {G. Chitragari and D. B. Mahler and B. J. Sumpio and P. A. Blume and B. E. Sumpio},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L370343216&from=export},
doi = {10.1016/j.cpm.2013.09.008},
issn = {1558-2302},
year = {2014},
date = {2014-01-01},
journal = {Clin. Podiatr. Med. Surg.},
volume = {31},
number = {1},
pages = {174–185},
address = {B.E. Sumpio, Yale University School of Medicine, 333 Cedar Street, BB 204, New Haven, CT 06520-8062, United States},
abstract = {Although the rate of lower limb amputation in patients with diabetes is decreasing, amputation still remains a major complication of diabetes. Prosthetics have been long used to help amputees ambulate. The last decade has seen many advances in prostheses with the enhanced understanding of the mechanics of ambulation and improved use of technology. This review describes the different types of prosthetic options available for below knee, ankle, and foot amputees, emphasizing the latest advances in prosthetic design. © 2014 Elsevier Inc.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
2010
Ludwigs, E.; Bellmann, M.; Schmalz, T.; Blumentritt, S.
Biomechanical differences between two exoprosthetic hip joint systems during level walking Artikel
In: Prosthet. Orthot. Int., Bd. 34, Nr. 4, S. 449–460, 2010, ISSN: 1746-1553.
@article{Ludwigs2010,
title = {Biomechanical differences between two exoprosthetic hip joint systems during level walking},
author = {E. Ludwigs and M. Bellmann and T. Schmalz and S. Blumentritt},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L360015209&from=export},
doi = {10.3109/03093646.2010.499551},
issn = {1746-1553},
year = {2010},
date = {2010-01-01},
journal = {Prosthet. Orthot. Int.},
volume = {34},
number = {4},
pages = {449–460},
address = {E. Ludwigs, Research Department, Otto Bock HealthCare GmbH, Hermann-Rein-Str. 2a, Gttingen, 37075, Germany},
abstract = {Previous studies have shown low end-user acceptance of a hip disarticulation style prosthesis and that the limitations of such prostheses, including poor gait pattern, socket discomfort, weight of the prosthesis, loss of mobility, instability and high energy consumption are a contributing factor. This study was initiated to determine if a new style of prosthetic hip joint could help to overcome some of the limitations concerning the gait pattern. The present study analyzed the gait pattern of six hip disarticulation amputee subjects. The objective was to compare two different prosthetic hip joints, both from Otto Bock HealthCare: The new Helix3D and the 7E7, which is based on the Canadian model proposed by McLaurin (1954). Kinematics and kinetics were recorded by an optoelectronic camera system with six CCD cameras and two force plates. During weight acceptance, the Helix3D extends considerably slower and reaches full extension later than the 7E7. The increased range of pelvic tilt observed with hip disarticulation amputees is significantly reduced (by 5±3 degrees) when using the Helix3D Hip Joint. In addition, this system showed increased stance phase knee joint flexion as well as increased maximum swing phase knee flexion angles compared to the 7E7. These motion analysis results show that the Helix3D Hip Joint can reduce gait abnormalities compared to the uniplanar design of the 7E7 hip joint. © 2010 ISPO.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}