TPress
Schmalz, T.; Schändlinger, J.; Schuler, M.; Bornmann, J.; Schirrmeister, B.; Kannenberg, A.; Ernst, M.
Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work Artikel
In: Int. J. Environ. Res. Public Health, Bd. 16, Nr. 23, 2019, ISSN: 1661-7827.
Abstract | Links | Schlagwörter: adult, article, biceps brachii muscle, biomechanics, body position, controlled study, deltoid muscle, electromyograph, electromyography, exoskeleton (rehabilitation), female, heart rate, human, human experiment, kinematics, latissimus dorsi muscle, male, metabolic parameters, normal human, oblique abdominal muscle, oxygen consumption, serratus muscle, skeletal muscle, trapezius muscle
@article{Schmalz2019,
title = {Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work},
author = {T. Schmalz and J. Schändlinger and M. Schuler and J. Bornmann and B. Schirrmeister and A. Kannenberg and M. Ernst},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2003259386&from=export},
doi = {10.3390/ijerph16234792},
issn = {1661-7827},
year = {2019},
date = {2019-01-01},
journal = {Int. J. Environ. Res. Public Health},
volume = {16},
number = {23},
address = {T. Schmalz, Clinical Research & Services/Biomechanics, Otto Bock SE & Co. KGaA, Göttingen, Germany},
abstract = {Overhead work activities can lead to shoulder pain and serious musculoskeletal disorders (WMSD), such as rotator cuff injury and degeneration. Recently developed exoskeletons show promising results in supporting workers in such activities. In this study, a novel exoskeleton was investigated for two different overhead tasks with twelve participants. To investigate the effects of the device, electromyographic (EMG) signals of different shoulder and adjacent muscles as well as kinematic and metabolic parameters were analyzed with and without the exoskeleton. The mean EMG amplitude of all evaluated muscles was significantly reduced when the exoskeleton was used for the overhead tasks. This was accompanied by a reduction in both heart rate and oxygen rate. The kinematic analysis revealed small changes in the joint positions during the tasks. This study demonstrated the biomechanical and metabolic benefits of an exoskeleton designed to support overhead work activities. The results suggest improved physiological conditions and an unloading effect on the shoulder joint and muscles which are promising indicators that the exoskeleton may be a good solution to reduce shoulder WMSD among workers who carry out overhead tasks on a regular basis.},
keywords = {adult, article, biceps brachii muscle, biomechanics, body position, controlled study, deltoid muscle, electromyograph, electromyography, exoskeleton (rehabilitation), female, heart rate, human, human experiment, kinematics, latissimus dorsi muscle, male, metabolic parameters, normal human, oblique abdominal muscle, oxygen consumption, serratus muscle, skeletal muscle, trapezius muscle},
pubstate = {published},
tppubtype = {article}
}
Volkmar, R.; Dosen, S.; Gonzalez-Vargas, J.; Baum, M.; Markovic, M.
Improving bimanual interaction with a prosthesis using semi-autonomous control Artikel
In: J. NeuroEng. Rehabil., Bd. 16, Nr. 1, 2019, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: adult, analytical equipment, article, bimanual interaction, controlled study, female, hand prosthesis, human, human experiment, inertial sensor, limb movement, male, motor control, motor performance, outcome assessment, priority journal, prosthesis, prosthesis design, semi autonomous control, sensor, task performance, vibrotactor, workload
@article{Volkmar2019,
title = {Improving bimanual interaction with a prosthesis using semi-autonomous control},
author = {R. Volkmar and S. Dosen and J. Gonzalez-Vargas and M. Baum and M. Markovic},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L629849607&from=export},
doi = {10.1186/s12984-019-0617-6},
issn = {1743-0003},
year = {2019},
date = {2019-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {16},
number = {1},
address = {M. Markovic, Department of Trauma Surgery Orthopedics and Plastic Surgery, University Medical Center Göttingen, Von-Siebold-Str. 3, Göttingen, Germany},
abstract = {Background: The loss of a hand is a traumatic experience that substantially compromises an individual's capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- A nd bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user's sound hand in performing bimanual interactions while decreasing cognitive burden.},
keywords = {adult, analytical equipment, article, bimanual interaction, controlled study, female, hand prosthesis, human, human experiment, inertial sensor, limb movement, male, motor control, motor performance, outcome assessment, priority journal, prosthesis, prosthesis design, semi autonomous control, sensor, task performance, vibrotactor, workload},
pubstate = {published},
tppubtype = {article}
}
Ernst, M.; Altenburg, B.; Bellmann, M.; Schmalz, T.
In: J. NeuroEng. Rehabil., Bd. 14, Nr. 1, 2017, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: adult, article, autoadaptive dorsiflexion stop, controlled study, foot prosthesis, Genium, ground reaction force, human, human experiment, informed consent, joint angle, joint torque, leg amputation, male, microprocessor, microprocessor controlled prosthetic feet, musculoskeletal function, musculoskeletal system parameters, priority journal, standing, task performance, transfemoral amputation, transtibial amputation, vertical ground reaction force
@article{Ernst2017,
title = {Standing on slopes - How current microprocessor-controlled prosthetic feet support transtibial and transfemoral amputees in an everyday task},
author = {M. Ernst and B. Altenburg and M. Bellmann and T. Schmalz},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L619264869&from=export},
doi = {10.1186/s12984-017-0322-2},
issn = {1743-0003},
year = {2017},
date = {2017-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {14},
number = {1},
address = {M. Ernst, Research Biomechanics, CRandS, Otto Bock HealthCare GmbH, Göttingen, Germany},
abstract = {Background: Conventional prosthetic feet like energy storage and return feet provide only a limited range of ankle motion compared to human ones. In order to overcome the poor rotational adaptability, prosthetic manufacturers developed different prosthetic feet with an additional rotational joint and implemented active control in different states. It was the aim of the study to investigate to what extent these commercially available microprocessor-controlled prosthetic feet support a natural posture while standing on inclines and which concept is most beneficial for lower limb amputees. Methods: Four unilateral transtibial and four unilateral transfemoral amputees participated in the study. Each of the subjects wore five different microprocessor-controlled prosthetic feet in addition to their everyday feet. The subjects were asked to stand on slopes of different inclinations (level ground, upward slope of 10°, and downward slope of -10°). Vertical ground reaction forces, joint torques and joint angles in the sagittal plane were measured for both legs separately for the different situations and compared to a non-amputee reference group. Results: Differences in the biomechanical parameters were observed between the different prosthetic feet and compared to the reference group for the investigated situations. They were most prominent while standing on a downward slope. For example, on the prosthetic side, the vertical ground reaction force is reduced by about 20%, and the torque about the knee acts to flex the joint for feet that are not capable of a full adaptation to the downward slope. In contrast, fully adaptable feet with an auto-adaptive dorsiflexion stop show no changes in vertical ground reaction forces and knee extending torques. Conclusions: A prosthetic foot that provides both, an auto-adaptive dorsiflexion stop and a sufficient range of motion for fully adapting to inclinations appears to be the key element in the prosthetic fitting for standing on inclinations in lower limb amputees. In such situations, this prosthetic concept appears superior to both, conventional feet with passive structures as well as feet that solely provide a sufficient range of motion. The results also indicate that both, transfemoral and transtibial amputees benefit from such a foot.},
keywords = {adult, article, autoadaptive dorsiflexion stop, controlled study, foot prosthesis, Genium, ground reaction force, human, human experiment, informed consent, joint angle, joint torque, leg amputation, male, microprocessor, microprocessor controlled prosthetic feet, musculoskeletal function, musculoskeletal system parameters, priority journal, standing, task performance, transfemoral amputation, transtibial amputation, vertical ground reaction force},
pubstate = {published},
tppubtype = {article}
}
Rigney, S. M.; Simmons, A.; Kark, L.
Mechanical characterization and comparison of energy storage and return prostheses Artikel
In: Med. Eng. Phys., Bd. 41, S. 90–96, 2017, ISSN: 1350-4533.
Abstract | Links | Schlagwörter: 1E90 Sprinter, article, biomechanics, body weight, Cheetah Xtreme, comparative study, controlled study, female, finite element analysis, Flex-foot Cheetah, foot prosthesis, force, gait, human, human experiment, mechanical torsion, rigidity, simulation, Vari-flex Modular
@article{Rigney2017,
title = {Mechanical characterization and comparison of energy storage and return prostheses},
author = {S. M. Rigney and A. Simmons and L. Kark},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L614136635&from=export},
doi = {10.1016/j.medengphy.2017.01.003},
issn = {1350-4533},
year = {2017},
date = {2017-01-01},
journal = {Med. Eng. Phys.},
volume = {41},
pages = {90–96},
address = {L. Kark, Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia},
abstract = {The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex® ModularTM, Flex-foot Cheetah and Cheetah Xtreme by Össur® and a 1E90 Sprinter by Ottobock®. Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics®, where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses’ loading response under bodyweight for an 80 kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0 Nmm−1 for the Vari-flex® ModularTM, Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics.},
keywords = {1E90 Sprinter, article, biomechanics, body weight, Cheetah Xtreme, comparative study, controlled study, female, finite element analysis, Flex-foot Cheetah, foot prosthesis, force, gait, human, human experiment, mechanical torsion, rigidity, simulation, Vari-flex Modular},
pubstate = {published},
tppubtype = {article}
}
Dosen, S.; Markovic, M.; Strbac, M.; Belic, M.; Kojic, V.; Bijelic, G.; Keller, T.; Farina, D.
In: IEEE Trans. Neural Syst. Rehabil. Eng., Bd. 25, Nr. 3, S. 183–195, 2017, ISSN: 1534-4320.
Abstract | Links | Schlagwörter: article, electrode, electromyogram, frequency modulation, hand prosthesis, human, human experiment, Michelangelo hand, muscle isometric contraction, myoelectric control, psychometry, rehabilitation equipment, spatial discrimination, tactile feedback, visual feedback
@article{Dosen2017,
title = {Multichannel electrotactile feedback with spatial and mixed coding for closed-loop control of grasping force in hand prostheses},
author = {S. Dosen and M. Markovic and M. Strbac and M. Belic and V. Kojic and G. Bijelic and T. Keller and D. Farina},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L615004930&from=export},
doi = {10.1109/tnsre.2016.2550864},
issn = {1534-4320},
year = {2017},
date = {2017-01-01},
journal = {IEEE Trans. Neural Syst. Rehabil. Eng.},
volume = {25},
number = {3},
pages = {183–195},
abstract = {Providing somatosensory feedback to the user of a myoelectric prosthesis is an important goal since it can improve the utility as well as facilitate the embodiment of the assistive system. Most often, the grasping force was selected as the feedback variable and communicated through one or more individual single channel stimulation units (e.g., electrodes, vibration motors). In the present study, an integrated, compact, multichannel solution comprising an array electrode and a programmable stimulator was presented. Two coding schemes (15 levels), spatial and mixed (spatial and frequency) modulation, were tested in able-bodied subjects, psychometrically and in force control with routine grasping and force tracking using real and simulated prosthesis. The results demonstrated that mixed and spatial coding, although substantially different in psychometric tests, resulted in a similar performance during both force control tasks. Furthermore, the ideal, visual feedback was not better than the tactile feedback in routine grasping. To explain the observed results, a conceptual model was proposed emphasizing that the performance depends on multiple factors, including feedback uncertainty, nature of the task and the reliability of the feedforward control. The study outcomes, specific conclusions and the general model, are relevant for the design of closed-loop myoelectric prostheses utilizing tactile feedback.},
keywords = {article, electrode, electromyogram, frequency modulation, hand prosthesis, human, human experiment, Michelangelo hand, muscle isometric contraction, myoelectric control, psychometry, rehabilitation equipment, spatial discrimination, tactile feedback, visual feedback},
pubstate = {published},
tppubtype = {article}
}
2019
Schmalz, T.; Schändlinger, J.; Schuler, M.; Bornmann, J.; Schirrmeister, B.; Kannenberg, A.; Ernst, M.
Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work Artikel
In: Int. J. Environ. Res. Public Health, Bd. 16, Nr. 23, 2019, ISSN: 1661-7827.
Abstract | Links | Schlagwörter: adult, article, biceps brachii muscle, biomechanics, body position, controlled study, deltoid muscle, electromyograph, electromyography, exoskeleton (rehabilitation), female, heart rate, human, human experiment, kinematics, latissimus dorsi muscle, male, metabolic parameters, normal human, oblique abdominal muscle, oxygen consumption, serratus muscle, skeletal muscle, trapezius muscle
@article{Schmalz2019,
title = {Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work},
author = {T. Schmalz and J. Schändlinger and M. Schuler and J. Bornmann and B. Schirrmeister and A. Kannenberg and M. Ernst},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2003259386&from=export},
doi = {10.3390/ijerph16234792},
issn = {1661-7827},
year = {2019},
date = {2019-01-01},
journal = {Int. J. Environ. Res. Public Health},
volume = {16},
number = {23},
address = {T. Schmalz, Clinical Research & Services/Biomechanics, Otto Bock SE & Co. KGaA, Göttingen, Germany},
abstract = {Overhead work activities can lead to shoulder pain and serious musculoskeletal disorders (WMSD), such as rotator cuff injury and degeneration. Recently developed exoskeletons show promising results in supporting workers in such activities. In this study, a novel exoskeleton was investigated for two different overhead tasks with twelve participants. To investigate the effects of the device, electromyographic (EMG) signals of different shoulder and adjacent muscles as well as kinematic and metabolic parameters were analyzed with and without the exoskeleton. The mean EMG amplitude of all evaluated muscles was significantly reduced when the exoskeleton was used for the overhead tasks. This was accompanied by a reduction in both heart rate and oxygen rate. The kinematic analysis revealed small changes in the joint positions during the tasks. This study demonstrated the biomechanical and metabolic benefits of an exoskeleton designed to support overhead work activities. The results suggest improved physiological conditions and an unloading effect on the shoulder joint and muscles which are promising indicators that the exoskeleton may be a good solution to reduce shoulder WMSD among workers who carry out overhead tasks on a regular basis.},
keywords = {adult, article, biceps brachii muscle, biomechanics, body position, controlled study, deltoid muscle, electromyograph, electromyography, exoskeleton (rehabilitation), female, heart rate, human, human experiment, kinematics, latissimus dorsi muscle, male, metabolic parameters, normal human, oblique abdominal muscle, oxygen consumption, serratus muscle, skeletal muscle, trapezius muscle},
pubstate = {published},
tppubtype = {article}
}
Volkmar, R.; Dosen, S.; Gonzalez-Vargas, J.; Baum, M.; Markovic, M.
Improving bimanual interaction with a prosthesis using semi-autonomous control Artikel
In: J. NeuroEng. Rehabil., Bd. 16, Nr. 1, 2019, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: adult, analytical equipment, article, bimanual interaction, controlled study, female, hand prosthesis, human, human experiment, inertial sensor, limb movement, male, motor control, motor performance, outcome assessment, priority journal, prosthesis, prosthesis design, semi autonomous control, sensor, task performance, vibrotactor, workload
@article{Volkmar2019,
title = {Improving bimanual interaction with a prosthesis using semi-autonomous control},
author = {R. Volkmar and S. Dosen and J. Gonzalez-Vargas and M. Baum and M. Markovic},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L629849607&from=export},
doi = {10.1186/s12984-019-0617-6},
issn = {1743-0003},
year = {2019},
date = {2019-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {16},
number = {1},
address = {M. Markovic, Department of Trauma Surgery Orthopedics and Plastic Surgery, University Medical Center Göttingen, Von-Siebold-Str. 3, Göttingen, Germany},
abstract = {Background: The loss of a hand is a traumatic experience that substantially compromises an individual's capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- A nd bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user's sound hand in performing bimanual interactions while decreasing cognitive burden.},
keywords = {adult, analytical equipment, article, bimanual interaction, controlled study, female, hand prosthesis, human, human experiment, inertial sensor, limb movement, male, motor control, motor performance, outcome assessment, priority journal, prosthesis, prosthesis design, semi autonomous control, sensor, task performance, vibrotactor, workload},
pubstate = {published},
tppubtype = {article}
}
2017
Ernst, M.; Altenburg, B.; Bellmann, M.; Schmalz, T.
In: J. NeuroEng. Rehabil., Bd. 14, Nr. 1, 2017, ISSN: 1743-0003.
Abstract | Links | Schlagwörter: adult, article, autoadaptive dorsiflexion stop, controlled study, foot prosthesis, Genium, ground reaction force, human, human experiment, informed consent, joint angle, joint torque, leg amputation, male, microprocessor, microprocessor controlled prosthetic feet, musculoskeletal function, musculoskeletal system parameters, priority journal, standing, task performance, transfemoral amputation, transtibial amputation, vertical ground reaction force
@article{Ernst2017,
title = {Standing on slopes - How current microprocessor-controlled prosthetic feet support transtibial and transfemoral amputees in an everyday task},
author = {M. Ernst and B. Altenburg and M. Bellmann and T. Schmalz},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L619264869&from=export},
doi = {10.1186/s12984-017-0322-2},
issn = {1743-0003},
year = {2017},
date = {2017-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {14},
number = {1},
address = {M. Ernst, Research Biomechanics, CRandS, Otto Bock HealthCare GmbH, Göttingen, Germany},
abstract = {Background: Conventional prosthetic feet like energy storage and return feet provide only a limited range of ankle motion compared to human ones. In order to overcome the poor rotational adaptability, prosthetic manufacturers developed different prosthetic feet with an additional rotational joint and implemented active control in different states. It was the aim of the study to investigate to what extent these commercially available microprocessor-controlled prosthetic feet support a natural posture while standing on inclines and which concept is most beneficial for lower limb amputees. Methods: Four unilateral transtibial and four unilateral transfemoral amputees participated in the study. Each of the subjects wore five different microprocessor-controlled prosthetic feet in addition to their everyday feet. The subjects were asked to stand on slopes of different inclinations (level ground, upward slope of 10°, and downward slope of -10°). Vertical ground reaction forces, joint torques and joint angles in the sagittal plane were measured for both legs separately for the different situations and compared to a non-amputee reference group. Results: Differences in the biomechanical parameters were observed between the different prosthetic feet and compared to the reference group for the investigated situations. They were most prominent while standing on a downward slope. For example, on the prosthetic side, the vertical ground reaction force is reduced by about 20%, and the torque about the knee acts to flex the joint for feet that are not capable of a full adaptation to the downward slope. In contrast, fully adaptable feet with an auto-adaptive dorsiflexion stop show no changes in vertical ground reaction forces and knee extending torques. Conclusions: A prosthetic foot that provides both, an auto-adaptive dorsiflexion stop and a sufficient range of motion for fully adapting to inclinations appears to be the key element in the prosthetic fitting for standing on inclinations in lower limb amputees. In such situations, this prosthetic concept appears superior to both, conventional feet with passive structures as well as feet that solely provide a sufficient range of motion. The results also indicate that both, transfemoral and transtibial amputees benefit from such a foot.},
keywords = {adult, article, autoadaptive dorsiflexion stop, controlled study, foot prosthesis, Genium, ground reaction force, human, human experiment, informed consent, joint angle, joint torque, leg amputation, male, microprocessor, microprocessor controlled prosthetic feet, musculoskeletal function, musculoskeletal system parameters, priority journal, standing, task performance, transfemoral amputation, transtibial amputation, vertical ground reaction force},
pubstate = {published},
tppubtype = {article}
}
Rigney, S. M.; Simmons, A.; Kark, L.
Mechanical characterization and comparison of energy storage and return prostheses Artikel
In: Med. Eng. Phys., Bd. 41, S. 90–96, 2017, ISSN: 1350-4533.
Abstract | Links | Schlagwörter: 1E90 Sprinter, article, biomechanics, body weight, Cheetah Xtreme, comparative study, controlled study, female, finite element analysis, Flex-foot Cheetah, foot prosthesis, force, gait, human, human experiment, mechanical torsion, rigidity, simulation, Vari-flex Modular
@article{Rigney2017,
title = {Mechanical characterization and comparison of energy storage and return prostheses},
author = {S. M. Rigney and A. Simmons and L. Kark},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L614136635&from=export},
doi = {10.1016/j.medengphy.2017.01.003},
issn = {1350-4533},
year = {2017},
date = {2017-01-01},
journal = {Med. Eng. Phys.},
volume = {41},
pages = {90–96},
address = {L. Kark, Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia},
abstract = {The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex® ModularTM, Flex-foot Cheetah and Cheetah Xtreme by Össur® and a 1E90 Sprinter by Ottobock®. Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics®, where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses’ loading response under bodyweight for an 80 kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0 Nmm−1 for the Vari-flex® ModularTM, Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics.},
keywords = {1E90 Sprinter, article, biomechanics, body weight, Cheetah Xtreme, comparative study, controlled study, female, finite element analysis, Flex-foot Cheetah, foot prosthesis, force, gait, human, human experiment, mechanical torsion, rigidity, simulation, Vari-flex Modular},
pubstate = {published},
tppubtype = {article}
}
Dosen, S.; Markovic, M.; Strbac, M.; Belic, M.; Kojic, V.; Bijelic, G.; Keller, T.; Farina, D.
In: IEEE Trans. Neural Syst. Rehabil. Eng., Bd. 25, Nr. 3, S. 183–195, 2017, ISSN: 1534-4320.
Abstract | Links | Schlagwörter: article, electrode, electromyogram, frequency modulation, hand prosthesis, human, human experiment, Michelangelo hand, muscle isometric contraction, myoelectric control, psychometry, rehabilitation equipment, spatial discrimination, tactile feedback, visual feedback
@article{Dosen2017,
title = {Multichannel electrotactile feedback with spatial and mixed coding for closed-loop control of grasping force in hand prostheses},
author = {S. Dosen and M. Markovic and M. Strbac and M. Belic and V. Kojic and G. Bijelic and T. Keller and D. Farina},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L615004930&from=export},
doi = {10.1109/tnsre.2016.2550864},
issn = {1534-4320},
year = {2017},
date = {2017-01-01},
journal = {IEEE Trans. Neural Syst. Rehabil. Eng.},
volume = {25},
number = {3},
pages = {183–195},
abstract = {Providing somatosensory feedback to the user of a myoelectric prosthesis is an important goal since it can improve the utility as well as facilitate the embodiment of the assistive system. Most often, the grasping force was selected as the feedback variable and communicated through one or more individual single channel stimulation units (e.g., electrodes, vibration motors). In the present study, an integrated, compact, multichannel solution comprising an array electrode and a programmable stimulator was presented. Two coding schemes (15 levels), spatial and mixed (spatial and frequency) modulation, were tested in able-bodied subjects, psychometrically and in force control with routine grasping and force tracking using real and simulated prosthesis. The results demonstrated that mixed and spatial coding, although substantially different in psychometric tests, resulted in a similar performance during both force control tasks. Furthermore, the ideal, visual feedback was not better than the tactile feedback in routine grasping. To explain the observed results, a conceptual model was proposed emphasizing that the performance depends on multiple factors, including feedback uncertainty, nature of the task and the reliability of the feedforward control. The study outcomes, specific conclusions and the general model, are relevant for the design of closed-loop myoelectric prostheses utilizing tactile feedback.},
keywords = {article, electrode, electromyogram, frequency modulation, hand prosthesis, human, human experiment, Michelangelo hand, muscle isometric contraction, myoelectric control, psychometry, rehabilitation equipment, spatial discrimination, tactile feedback, visual feedback},
pubstate = {published},
tppubtype = {article}
}
2019
Schmalz, T.; Schändlinger, J.; Schuler, M.; Bornmann, J.; Schirrmeister, B.; Kannenberg, A.; Ernst, M.
Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work Artikel
In: Int. J. Environ. Res. Public Health, Bd. 16, Nr. 23, 2019, ISSN: 1661-7827.
@article{Schmalz2019,
title = {Biomechanical and metabolic effectiveness of an industrial exoskeleton for overhead work},
author = {T. Schmalz and J. Schändlinger and M. Schuler and J. Bornmann and B. Schirrmeister and A. Kannenberg and M. Ernst},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L2003259386&from=export},
doi = {10.3390/ijerph16234792},
issn = {1661-7827},
year = {2019},
date = {2019-01-01},
journal = {Int. J. Environ. Res. Public Health},
volume = {16},
number = {23},
address = {T. Schmalz, Clinical Research & Services/Biomechanics, Otto Bock SE & Co. KGaA, Göttingen, Germany},
abstract = {Overhead work activities can lead to shoulder pain and serious musculoskeletal disorders (WMSD), such as rotator cuff injury and degeneration. Recently developed exoskeletons show promising results in supporting workers in such activities. In this study, a novel exoskeleton was investigated for two different overhead tasks with twelve participants. To investigate the effects of the device, electromyographic (EMG) signals of different shoulder and adjacent muscles as well as kinematic and metabolic parameters were analyzed with and without the exoskeleton. The mean EMG amplitude of all evaluated muscles was significantly reduced when the exoskeleton was used for the overhead tasks. This was accompanied by a reduction in both heart rate and oxygen rate. The kinematic analysis revealed small changes in the joint positions during the tasks. This study demonstrated the biomechanical and metabolic benefits of an exoskeleton designed to support overhead work activities. The results suggest improved physiological conditions and an unloading effect on the shoulder joint and muscles which are promising indicators that the exoskeleton may be a good solution to reduce shoulder WMSD among workers who carry out overhead tasks on a regular basis.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
Volkmar, R.; Dosen, S.; Gonzalez-Vargas, J.; Baum, M.; Markovic, M.
Improving bimanual interaction with a prosthesis using semi-autonomous control Artikel
In: J. NeuroEng. Rehabil., Bd. 16, Nr. 1, 2019, ISSN: 1743-0003.
@article{Volkmar2019,
title = {Improving bimanual interaction with a prosthesis using semi-autonomous control},
author = {R. Volkmar and S. Dosen and J. Gonzalez-Vargas and M. Baum and M. Markovic},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L629849607&from=export},
doi = {10.1186/s12984-019-0617-6},
issn = {1743-0003},
year = {2019},
date = {2019-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {16},
number = {1},
address = {M. Markovic, Department of Trauma Surgery Orthopedics and Plastic Surgery, University Medical Center Göttingen, Von-Siebold-Str. 3, Göttingen, Germany},
abstract = {Background: The loss of a hand is a traumatic experience that substantially compromises an individual's capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- A nd bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user's sound hand in performing bimanual interactions while decreasing cognitive burden.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
2017
Ernst, M.; Altenburg, B.; Bellmann, M.; Schmalz, T.
In: J. NeuroEng. Rehabil., Bd. 14, Nr. 1, 2017, ISSN: 1743-0003.
@article{Ernst2017,
title = {Standing on slopes - How current microprocessor-controlled prosthetic feet support transtibial and transfemoral amputees in an everyday task},
author = {M. Ernst and B. Altenburg and M. Bellmann and T. Schmalz},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L619264869&from=export},
doi = {10.1186/s12984-017-0322-2},
issn = {1743-0003},
year = {2017},
date = {2017-01-01},
journal = {J. NeuroEng. Rehabil.},
volume = {14},
number = {1},
address = {M. Ernst, Research Biomechanics, CRandS, Otto Bock HealthCare GmbH, Göttingen, Germany},
abstract = {Background: Conventional prosthetic feet like energy storage and return feet provide only a limited range of ankle motion compared to human ones. In order to overcome the poor rotational adaptability, prosthetic manufacturers developed different prosthetic feet with an additional rotational joint and implemented active control in different states. It was the aim of the study to investigate to what extent these commercially available microprocessor-controlled prosthetic feet support a natural posture while standing on inclines and which concept is most beneficial for lower limb amputees. Methods: Four unilateral transtibial and four unilateral transfemoral amputees participated in the study. Each of the subjects wore five different microprocessor-controlled prosthetic feet in addition to their everyday feet. The subjects were asked to stand on slopes of different inclinations (level ground, upward slope of 10°, and downward slope of -10°). Vertical ground reaction forces, joint torques and joint angles in the sagittal plane were measured for both legs separately for the different situations and compared to a non-amputee reference group. Results: Differences in the biomechanical parameters were observed between the different prosthetic feet and compared to the reference group for the investigated situations. They were most prominent while standing on a downward slope. For example, on the prosthetic side, the vertical ground reaction force is reduced by about 20%, and the torque about the knee acts to flex the joint for feet that are not capable of a full adaptation to the downward slope. In contrast, fully adaptable feet with an auto-adaptive dorsiflexion stop show no changes in vertical ground reaction forces and knee extending torques. Conclusions: A prosthetic foot that provides both, an auto-adaptive dorsiflexion stop and a sufficient range of motion for fully adapting to inclinations appears to be the key element in the prosthetic fitting for standing on inclinations in lower limb amputees. In such situations, this prosthetic concept appears superior to both, conventional feet with passive structures as well as feet that solely provide a sufficient range of motion. The results also indicate that both, transfemoral and transtibial amputees benefit from such a foot.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
Rigney, S. M.; Simmons, A.; Kark, L.
Mechanical characterization and comparison of energy storage and return prostheses Artikel
In: Med. Eng. Phys., Bd. 41, S. 90–96, 2017, ISSN: 1350-4533.
@article{Rigney2017,
title = {Mechanical characterization and comparison of energy storage and return prostheses},
author = {S. M. Rigney and A. Simmons and L. Kark},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L614136635&from=export},
doi = {10.1016/j.medengphy.2017.01.003},
issn = {1350-4533},
year = {2017},
date = {2017-01-01},
journal = {Med. Eng. Phys.},
volume = {41},
pages = {90–96},
address = {L. Kark, Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia},
abstract = {The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex® ModularTM, Flex-foot Cheetah and Cheetah Xtreme by Össur® and a 1E90 Sprinter by Ottobock®. Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics®, where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses’ loading response under bodyweight for an 80 kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0 Nmm−1 for the Vari-flex® ModularTM, Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
Dosen, S.; Markovic, M.; Strbac, M.; Belic, M.; Kojic, V.; Bijelic, G.; Keller, T.; Farina, D.
In: IEEE Trans. Neural Syst. Rehabil. Eng., Bd. 25, Nr. 3, S. 183–195, 2017, ISSN: 1534-4320.
@article{Dosen2017,
title = {Multichannel electrotactile feedback with spatial and mixed coding for closed-loop control of grasping force in hand prostheses},
author = {S. Dosen and M. Markovic and M. Strbac and M. Belic and V. Kojic and G. Bijelic and T. Keller and D. Farina},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L615004930&from=export},
doi = {10.1109/tnsre.2016.2550864},
issn = {1534-4320},
year = {2017},
date = {2017-01-01},
journal = {IEEE Trans. Neural Syst. Rehabil. Eng.},
volume = {25},
number = {3},
pages = {183–195},
abstract = {Providing somatosensory feedback to the user of a myoelectric prosthesis is an important goal since it can improve the utility as well as facilitate the embodiment of the assistive system. Most often, the grasping force was selected as the feedback variable and communicated through one or more individual single channel stimulation units (e.g., electrodes, vibration motors). In the present study, an integrated, compact, multichannel solution comprising an array electrode and a programmable stimulator was presented. Two coding schemes (15 levels), spatial and mixed (spatial and frequency) modulation, were tested in able-bodied subjects, psychometrically and in force control with routine grasping and force tracking using real and simulated prosthesis. The results demonstrated that mixed and spatial coding, although substantially different in psychometric tests, resulted in a similar performance during both force control tasks. Furthermore, the ideal, visual feedback was not better than the tactile feedback in routine grasping. To explain the observed results, a conceptual model was proposed emphasizing that the performance depends on multiple factors, including feedback uncertainty, nature of the task and the reliability of the feedforward control. The study outcomes, specific conclusions and the general model, are relevant for the design of closed-loop myoelectric prostheses utilizing tactile feedback.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}
2013
Fligge, N.; Urbanek, H.; der Smagt, P. Van
Relation between object properties and EMG during reaching to grasp Artikel
In: J. Electromyogr. Kinesiology, Bd. 23, Nr. 2, S. 402–410, 2013, ISSN: 1873-5711.
@article{Fligge2013,
title = {Relation between object properties and EMG during reaching to grasp},
author = {N. Fligge and H. Urbanek and P. Van der Smagt},
url = {https://www.embase.com/search/results?subaction=viewrecord&id=L52331059&from=export},
doi = {10.1016/j.jelekin.2012.10.010},
issn = {1873-5711},
year = {2013},
date = {2013-01-01},
journal = {J. Electromyogr. Kinesiology},
volume = {23},
number = {2},
pages = {402–410},
address = {N. Fligge, German Aerospace Center (DLR), Center for Robotics and Mechatronics, Muenchner Strasse 20, D-82234 Oberpfaffenhofen-Wessling, Germany},
abstract = {In order to stably grasp an object with an artificial hand, a priori knowledge of the object's properties is a major advantage, especially to ensure subsequent manipulation of the object held by the hand. This is also true for hand prostheses: pre-shaping of the hand while approaching the object, similar to able-bodied, allows the wearer for a much faster and more intuitive way of handling and grasping an object. For hand prostheses, it would be advantageous to obtain this information about object properties from a surface electromyography (sEMG) signal, which is already present and used to control the active prosthetic hand.We describe experiments in which human subjects grasp different objects at different positions while their muscular activity is recorded through eight sEMG electrodes placed on the forearm. Results show that sEMG data, gathered before the hand is in contact with the object, can be used to obtain relevant information on object properties such as size and weight. © 2012 Elsevier Ltd.},
keywords = {},
pubstate = {published},
tppubtype = {article}
}